Reaction #4109596
Related Literature (1)
openreactiondata ↗doi:10.1039/C8SC04228D
Conditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-8bf8beb8a81a4d008501f47813525d78No renderable structure data available
CCCCN1CCNCC1Chemical Intermediate
Structures, identifiers and computed properties have been matched to the database record by CAS.
| Intermediates | 1-butylpiperazine |
|---|---|
| IUPAC Name | — |
| CAS Number | 5610-49-1 |
| Database ID | 424322 |
| Molecular Formula | — |
| Molecular Weight | — |
Product Information
1-butylpiperazine (CAS 5610-49-1) product identity, structure identifiers and related reaction data for chemical intermediate research and sourcing review.
Potential Applications
For professional research and industrial use only
Database ID 424322
Safety Notice
For professional research and industrial use only. Review the supplier safety data sheet before handling.
Synthesis data
12 reactions · 12 references
Conditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-8bf8beb8a81a4d008501f47813525d78Conditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-f6ebfd9d376d47f9907ef144acbb4bdeConditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-0d6dbc4c627047038d8f73d916e7ca31Conditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-d971f875b64f4a189d102369bb02ba86Conditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-5c3069c0ced249c0a98d64f79eb7b62cConditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-6ec7929c6ffe4a049eb35e4b4845e0c9Conditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-18003e7b240349109faa81235c437780Conditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-32e28bbcb760462da3b0bbbf6aa0a42fConditions: temp:25.01; pressure:0.00; stir:
Procedure: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
Source ID: ord-048163b293674e3ea711b34f78b56fe4Conditions: temp:25.01; pressure:0.00; stir:
Procedure: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
Source ID: ord-9b2f4455068b4aa6b8eada24dcef04c7Conditions: temp:25.01; pressure:0.00; stir:
Procedure: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
Source ID: ord-8b5d6b0a4fbf4a87bc662026ab356579Conditions: temp:25.01; pressure:0.00; stir:
Procedure: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
Source ID: ord-a5b8d6f4e008476e8e63781b53bd3e4ePubChem References
These sources are listed in the compound's public database record.
Related Products
12 related records
CAS 54722-40-6
CAS 1021145-64-1
CAS 82394-26-1
CAS 115281-17-9
CAS 22763-69-5
CAS 58910-31-9
CAS 50866-75-6
CAS 91015-23-5
CAS 82394-25-0
CAS 63207-03-4
CAS 54256-45-0
CAS 54722-41-7
Request a Quote
Send the required specification, quantity, destination and intended use. The CATO team will review availability and respond.