Reaction #4173364
Related Literature (1)
openreactiondata ↗doi:10.1039/C8SC04228D
Conditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-f8291e7ff8cc4883829f141d8cf6b47fNo renderable structure data available
C1=CC(=CC=C1CN)BrChemical Intermediate
Structures, identifiers and computed properties have been matched to the database record by CAS.
| Intermediates | (4-bromophenyl)methanamine |
|---|---|
| IUPAC Name | — |
| CAS Number | 3959-07-7 |
| Database ID | 77571 |
| Molecular Formula | — |
| Molecular Weight | — |
Product Information
(4-bromophenyl)methanamine (CAS 3959-07-7) product identity, structure identifiers and related reaction data for chemical intermediate research and sourcing review.
Potential Applications
For professional research and industrial use only
Database ID 77571
Safety Notice
For professional research and industrial use only. Review the supplier safety data sheet before handling.
Synthesis data
12 reactions · 12 references
Conditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-f8291e7ff8cc4883829f141d8cf6b47fConditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-8eeb3653300441068a87473ca31c56f8Conditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-dbd705babfa241238a7115aa8d3b48ffConditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-0d05ed2749604a4c9a39ab2656303772Conditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-dbfa258f8560460393207f22a63bed80Conditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-a685de108ec346f2a30ce3f53d7dad03Conditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-81a77ea64f6848ff81cfcb028903ed02Conditions: temp:0.00; pressure:0.00; stir:
Source ID: ord-71549d0115464443a1458ee863eaf7f1Conditions: temp:25.01; pressure:0.00; stir:
Procedure: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
Source ID: ord-77c08065eaf0491e8d1db9df5cca6ca9Conditions: temp:25.01; pressure:0.00; stir:
Procedure: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
Source ID: ord-b9272f47b9094eea90b4d91d12a30d1fConditions: temp:25.01; pressure:0.00; stir:
Procedure: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
Source ID: ord-49e279226cca4d9fbb7b17d4b6748e33Conditions: temp:25.01; pressure:0.00; stir:
Procedure: 150 uL of MeCN/H2O (1:1) mixed solvent was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 150 uL of internal standard solution was dispensed separately into each plate using the 96-tip head of the Tecan Evo-200. 10 uL aliquot taken from reaction vials, and added to pre-filled wells in the transfer plate. 380 uL MeCN solvent were added to the transfer plate 20 uL taken from transfer plate to filter plate 1 for LCMS analysis 180 uL MeCN added to filter plate 1 for LCMS analysis 10 uL taken from transfer plate to filter plate 2 for TOF-DESI analysis 190 uL MeCN added to filter plate 2 for TOF-DESI analysis the 96-well filter plates were centrifuged for 2.5 min at 3000 RPM
Source ID: ord-05756db9559e4578a3ba65394e9cc118PubChem References
These sources are listed in the compound's public database record.
Related Products
12 related records
CAS 58971-11-2
CAS 5465-63-4
CAS 26177-44-6
CAS 74702-93-5
CAS 17797-12-5
CAS 698-67-9
CAS 106-38-7
CAS 100-81-2
CAS 556-96-7
CAS 2076-56-4
CAS 22265-36-7
CAS 127168-84-7
Request a Quote
Send the required specification, quantity, destination and intended use. The CATO team will review availability and respond.
